Sew 1810 EL
|
|
FEATURES
● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).
SPECIFICATIONS
Current settings
10-50mA@230Vac>
Current selection
Knob
Frequency of operation
50/60 Hz Sinusoidal
Over-Temperature Protection
NO
Operating voltage (L-E)
230 Vac ±15%
Meter accuracy
±1% of full scale
Protection
Fused (200mA 250V)
Operating temperature
-5°C to 45°C
Storage temperature
-10°C to 55°C
Dimensions
170(L) × 165(W) × 92(D)mm
Weight
Approx. 730g
Safety standard
EN 50081-1 EN 50082-1
|
Analogue ELCB Testers
|
|
|
|
|
|
|
Sew 1811 EL
|
|
FEATURES
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Suitable for industrial applications.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto off and off override.● Polarity Trip indicator (Positive of Negative Phase).
SPECIFICATIONS
Current settings
0-999mAac / 50Hz
Current selection
Knob
Phase start selection 0° and 180°
Referenced to Earth Yes
Over-temperature protection
Yes
Phase polarity trip Indicator
Referenced to Earth Yes
Operating voltage (L-E)
110 Vac to 450 Vac
Timer resolution
1ms (Max. Time = 99.999s)
Timer accuracy
1ms ±1ms
Current accuracy
±1% ±1mA
Current resolution
1mA
Voltmeter accuracy (50Hz)
50-350 Vac = ±2%±1V 350-450 Vac = ±5%±1V
Voltameter resolution
... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 1812 EL
|
|
FEATURES
● Microprocessor-controlled.● 2Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity shown on LCD display.● Auto-off and off override.● Polarity Trip indicator (Positive of Negative Phase).● Wiring polarity indicator.● Measure voltage and frequency between Line and Earth before testing.
SPECIFICATIONS
Current settings
3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 30mA, 35mA, 50mA, 100mA, 125mA, 150mA, 175mA, 250mA, 300mA, 375mA, 500mA.
Current selection
Rotary switch selector
Phase start selection 0° and 180°
Referenced to Earth Yes
Over-temperature protection
Yes (3 sensors)
Wiring correctness indication
Yes (LEDs)
Trip indicator
Yes (LEDs)
Phase polarity trip Indicator
Yes (LCD) Referenced to Earth
Voltmeter (L-E)
20Vac ~ 280Vac
Timer resolution
1ms (Max. Time = 2.999s)
Timer... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 1813 EL
|
|
FEATURES
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
SPECIFICATIONS
System voltage (50Hz / 60Hz)
550V 380V 240V
Current settings
2-999mA ac
Current selection
Knob
Phase start selection referenced to earth
0° and 180°
Over-temperature protection
Yes
Wiring correction indication
Yes
Phase polarity trip indicator
Yes
Operating voltage (L-E)
110 Vac to 317 Vac
Timer resolution
1ms (Max. Time=19.999s)
Timer accuracy
1ms ±1ms
... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 2712 EL
|
|
FEATURES
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● 50Hz and 60Hz operation.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Over temperature protection.● Over voltage protection.● Fuse protection.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● Frequency measurement indication.
SPECIFICATIONS
Operating voltage (L-E) (50Hz or 60 Hz)
Version A : 240 Vac Version B : 230 Vac Version C : 220 Vac Version D : 110 Vac
Current settings
3mA, 5mA, 10mA, 15mA, 20mA, 30mA, 50mA, 100mA, 150mA, 250mA, 300mA, 500mA.
Current selection
Rotary switch selector
Phase angle setting
0° and 180° selectable
Wiring correctness indication
Yes (LEDs)
Trip indicator
Yes (LCD)
Phase polarity trip indicator
Yes... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 2820 EL
|
|
FEATURES
● Microprocessor-controlled.● Operating voltage 100-450V L-E.● Rated current 999mA, at 317V AC/50Hz.● Checks ELCB trip time and trip point (sensitivity).● Auto off and auto ranging.● Phase angle selection(0° / 180°).● Indicates tripping phase angle.● Impact resistant enclosure.● Over temperature shut-down.● Transient protection.● Suitable for heavy industrial use.● Fused.
SPECIFICATIONS
Trip current-range
0-1A at 317V (Auto-Rang Programmable)
Trip current- resolution
1mA
Operating voltage (L-E)
100 - 450V
Phase angle setting
0° and 180° selectable
Timer-max
99.999s
Timer resolution
1ms
Typical Accuracy
Trip-current
±1%rdg±1mA
Trip-time
±1%rdg±1dgt
Voltage
±3%rdg±1dgt
Operating temperature - humidity
-10°C to +40°C 80% Max. relative humidity
Dimensions
170(L) × 120(W) × 95(D)mm
Weight (battery included)
Approx. 800g
Power source
1.5 (AA) × 8
Safety standard
EN 61010-1 CAT III 450V EN... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 4112 EL
|
|
FEATURES
● Microprocessor-controlled.● 2 Lines × 16 Characters LCD.● Very low consumption.● Menu-driven.● Accurate digital readout of disconnection time.● Automatic data hold function.● Zero Crossing Circuitry permit testing at 0° or 180°.● Disconnection Phase Polarity Shown on LCD.● Auto off and off override.● Polarity Trip indicator (Positive or Negative Phase).● Wiring polarity indicator.● Measure voltage between line and earth before testing.● Indicates frequency of voltage L-E.
SPECIFICATIONS
Current settings
3mA, 5mA, 7mA, 10mA, 15mA, 20mA, 30mA, 35mA, 50mA, 100mA, 125mA, 150mA, 175mA, 250mA, 300mA, 375mA, 500mA.
Current selection
Rotary switch
Phase start selection 0° and 180°
Referenced to Earth Yes
Over-temperature protection
Yes
Wiring correctness indication
Yes
Trip indicator
Yes
Phase polarity trip Indicator
Yes
Operating voltage (L-E)
Referenced to Earth 240Vac-50Hz or 60Hz Voltage Model (Vac)
Timer resolution
1ms (Max. Time=19.99s)
Timer accuracy
1ms... |
Digital ELCB Testers
|
|
|
|
|
|
|
Sew 6220 EL
|
|
FEATURES
● Microprocessor technology ensures high
performance accuracy and reliability.● Fully programmable via tactile key pad.● Direct readout of disconnection, time or current.
● Voltage measured during test.● Housed in a heavy duty carry case.● Suitable for all industrial, mining and domestic
environments.● Display can be customized for special orders.● Indicate voltage and trip Current/Time.● Use binary principle.● True resistor switching.
SPECIFICATIONS
Rated tripping current at 317V
1000mA (2000mA on special orders)
Lowest resolution
1mA
System voltage
230 / 380 / 550V (50Hz)
Maximum trip time
99.99s
Highest resolution
10ms
Typical Accuracy
Rated trip current
±1%rdg ± 2dgt
Voltage range
±1%rdg ± 1dgt
Trip-time
±1%rdg ± 2dgt
Voltage
0°C to 40°C
Operating-humidity
80% Max. relative humidity
Dimensions
330(L) × 260(W) × 160(D)mm
Weight (battery included)
Approx. 3700g
Power source
1.5V “C” × 8... |
Digital ELCB Testers
|
|
|
|
|