|
|
Sew 1152 MF
|
|
FEATURES
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
250V / 500V / 1000V
Measuring ranges
0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
PI Function
ˇ
DAR Function
ˇ
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
ˇ
|
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 1153 AI
|
|
FEATURES
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
|
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 1154 TMF
|
|
FEATURES
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
50V / 100V / 125V / 250V / 500V /1000V
Measuring ranges
0.1M~400MΩ / 0.1M~800MΩ / 0.1M~1GΩ / 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
ˇ
|
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 1155 TMF
|
|
FEATURES
● Microprocessor-controlled.● Automatic voltmeter AC/DC at Start/Reset.● Auto range● Auto off.● Battery test.● Battery test at switch ON/Reset.● Safety voltmeter before each test.● Auto discharge on all test and all ranges.● Leads Auto-Null key.● Test Auto-Stop.● Smart hold & stop on voltmeter ac/dc.● Ener-Save feature to extend battery life.● Continuity short circuit current > 220mA.● Continuity open circuit voltage of 5Vdc.● Nominal voltage @ 1mA on all insulation ranges.● Accept 8 rechargeable batteries or Alkaline of normal.● BS 16 edition.
SPECIFICATIONS
Insulation Resistance
Test voltage
50V / 100V / 125V / 250V / 500V /1000V
Measuring ranges
0.1M~400MΩ / 0.1M~800MΩ / 0.1M~1GΩ / 0.2M~2GΩ / 0.2M~4GΩ / 0.2M~8GΩ
Continuity
Range
0.01Ω~1999Ω
Voltmeter
AC V
0-700V
DC V
0-950V
PI Function
ˇ
DAR Function
ˇ
Metal Oxyde Varistor
ˇ
Gas Arrester Voltage
ˇ
|
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 2788 MF
|
|
FEATURES
● Auto-range microprocessor-controlled.● Insulation test voltages : 250, 500, 1000VΩ.● Mov / protection devices test.● Gas Arrester function.● Automatic voltmeter AC/DC at Start/Reset.● Test ON-OFF.● Battery test.● Safety voltmeter before each test.● Auto-discharge on all test and all ranges.● Leads Auto-null key.● Test Auto-stop.● Smart hold & stop on voltmeter AC/DC.● Ener-Save™.
SPECIFICATIONS
Insulation Resistance
Test voltage (DC V)
250V / 500V / 1000V
Measuring ranges
250V : 0.2MΩ~2GΩ 500V : 0.2MΩ~4GΩ 1000V : 0.2MΩ~8GΩ
Accuracy
0.2MΩ~4GΩ : ±3%rdg 4MΩ~8GΩ : ±5%rdg
Nominal voltage rated
1mA
Short circuit current
1.2mA
Polarization index (PI)
ˇ
Detective absorption ratio (DAR)
ˇ
Continuity
Range
0.01~100Ω / 100 ~300Ω / 300~1999Ω
Resolution
2 counts
Accuracy
0.01~100Ω : ±1.0%rdg 100~300Ω : ±1.5%rdg 300~1999Ω : ±2.0%rdg
Auto-null
up to 5Ω
Buzzer
up to 3Ω
KΩ... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 4101 IN
|
|
FEATURES
● Measures Insulation Resistance, voltage (AC-DC) measurements.● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
SPECIFICATIONS
Insulation Test
Test voltage (DC V)
250V / 500V / 1000V
Output voltage @ 1mA
Rated test Voltage +10% Max
Measuring ranges
0.2M~2G / 0.2M-4G / 0.2M-8GΩ
Accuracy
0.2M~4GΩ : ±3%rdg 4GΩ~8GΩ : ±5%rdg
When voltage is constant, Current is limited at
1.2mA
Short circuit current
4mA Max.
Continuity Test
Measuring ranges
0.01-1999Ω
Accuracy
0.01-100Ω : ±1.0%rdg 100-300Ω : ±1.5%rdg 300-1999Ω : ±2.0%rdg
Short circuit current
... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 4102 MF
|
|
FEATURES
● Measures Insulation Resistance, voltage (AC-DC) measurements● Automatic hold facility.● Continuity test with a short circuit current of minimum 200mA.● MOV and Gas Arrester Testing.● Energy conservation is feature.● EnerSave™ limits the test duration to about 10 Seconds to save energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
SPECIFICATIONS
Insulation Test
Test voltage (DC V)
250V / 500V / 1000V
Output voltage @ 1mA
Rated test Voltage +10% Max
Measuring ranges
0.2M~2G / 0.2M-4G / 0.2M-8GΩ
Accuracy
0.2M~4GΩ : ±3%rdg 4GΩ~8GΩ : ±5%rdg
When voltage is constant, Current is limited at
1.2mA
Short circuit current
4mA Max.
Continuity Test
Measuring ranges
0.01-1999Ω
Accuracy
0.01-100Ω : ±1.0%rdg 100-300Ω : ±1.5%rdg 300-1999Ω :... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|
|
|
Sew 4153 IN
|
|
FEATURES
● Microprocessor-controlled.● Measures Insulation Resistance, voltage (AC-DC) measurements with automatic hold facility, diode, ohm, and continuity with a short circuit current of minimum 220mA.● Auto-off function.● Energy conservation feature.● Ener-Save™ limit the test duration to about 10 Seconds.● Quick Test and EnerSave™ are unique features. Both saves energy.● No moving parts. All calibration are saved internally in a non volatile memory.● Easy calibration at any facility around the world.● Operates with rechargeable batteries, alkaline or low cost general purpose batteries.● Low cost maintenance, calibration, and ownership.● Complies to all the latest regulations, including UK.
SPECIFICATIONS
Insulation Test
Test voltage (DC V) and Measuring ranges
250V / 0.2M~2GΩ 500V / 0.2M-4GΩ 1000V / 0.2M-8GΩ
Output voltage @ 1mA
Rated test Voltage +10% Max
Accuracy
0.2M~4GΩ : ±3%rdg 4GΩ~8GΩ : ±5%rdg
When voltage is constant, Current is limited at
... |
Insulation & Multifunction Testers (LCD Display)
|
|
|
|
|