Sew ST-3602
|
|
FEATURES
● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges
SPECIFICATIONS
AC A
200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz)
AC V
200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)
DC A
200 / 1500A ±(2%rdg+4dgt)
DC V
200 / 1000V ±(1%rdg+2dgt)
Ω
200 / 1500Ω ±(1.5%rdg+2dgt)
Diode check
0-1500mV ±(1.5%rdg+2dgt)
Buzzer
Resistance is less than 100Ω
Conductor size
55mm Max.
Operating temperature
0ºC ~ 40ºC
Humidity
85% R.H.
Current consumption
Approx. 10mA
Dimensions
245(L) × 70(W) × 41.7(D)mm
Weight (battery Included)
Approx. 480g
Power source
9V(6F22) × 1
|
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3800 CL
|
|
FEATURES
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
───
LCD backlight display
───
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 420g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3801 CL
|
|
FEATURES
● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
ˇ
LCD backlight display
ˇ
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 430g
Power source
9V(6F22) × 1
Safety... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3810 CL
|
|
FEATURES
● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
SPECIFICATIONS
AC A
400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz
AC V
400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz
DC A
400A / 1000A ±(1.5%rdg+3dgt)
DC V
400V / 600V ±(0.75%rdg+3dgt)
Ω
400Ω / 2000Ω ±(1.0%rdg+3dgt)
Flashlight
───
LCD backlight display
───
Buzzer sounds
<38Ω
Conductor size
40mm Max.
Low battery Indication
Dimensions
255(L) × 80(W) × 35(D)mm
Weight (battery included)
Approx. 420g
Power source
9V(6F22) × 1
Safety standard
EN 61010-1 CAT III 600V EN... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3900 CL
|
|
FEATURES
● 4000- count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt) 40~500Hz
DC A
400.0/2000A... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3902 CL
|
|
FEATURES
● 2000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
200.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
200.0/2000A... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3904 CL
|
|
FEATURES
● 4000 - count LCD.● Full automatic measurement. ◎ Voltage measurement. ◎ Current measurement. ◎ Resistor measurement. ◎ Capacitor measurement ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded banana plugs and recessed input terminals.
SPECIFICATIONS
AC A
400.0/2000A (40~500Hz) 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
AC V
400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt) 40~500Hz
DC A
400.0/2000A 0~1500A ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt)
DC V
400.0mV/4.000/40.00/400.0/1000V... |
AC/DC Clamp Meters
|
|
|
|
|
|
|
Sew 3920 CL
|
|
FEATURES
● Designed for testing AC current and AC voltage. ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.
SPECIFICATIONS
AC Current
Ranges
Accuracy
50/60Hz
WIDE
200mA(0~199.9mA)
±(1.5%rdg+2dgt)
40/1000Hz : ±(3.0%rdg+2dgt)
2A (0~1.999A)
20A(0~19.99A)
200A(0~199.9A)
±(2.0%rdg+2dgt)
40/1000Hz : ±(3.5%rdg+2dgt)
0-500A
±(2.0%rdg+2dgt)
40/1000Hz : ±(3.5%rdg+2dgt)
501-1000A
±5.5%rdg
40/1000Hz : ±10%rdg
AC Voltage
Ranges
AC 200V/AC600V
Resolution
0.1V / 1V
Accuracy
±(1.5%rdg+3dgt)
GENERAL
Conductor size
55mm Max.
Operating principle
Dual slope integration
Display
3½ digit (2000 counts)
Low battery indication
“ “ sign appears on the display when the battery voltage drops below accurate operating level
... |
Leakage Clamp Meters
|
|
|
|
|