Hot-wire anemometers


 

 

 
  • Filter

Fast Response Probe. Air Flow Volume Instant / Avg / 2/3 Vmax Flow Measurement. Velocity m/s, ft/min, knots, km/hr, mph. Data hold & Maximum / Minimum function. Manual data memory and read function (10 x 99 sets).  

Fast Response Probe. Air Flow Volume. Instant / Avg / 2/3 Vmax Flow Measurement. Velocity m/s, ft/min, knots, km/hr, mph. Temperature & Humidity measurement.  

   - Air velocity : 0.2 to 20.0 m/s    - Air temperature : 0 ℃ to 50 ℃    - Type K/J thermometer : -50.0 to 1300.0 ℃  

This unit covers the range from 0 to 20 m/s and the temperature range from -20 to 70 °C. The compact TST0067 uses a heated wire NTC sensor to measure velocity and temperature for applications in the HVAC industry.

風速測定値 0.1~5.00 ,5.0~50.0 m/s            (自動切替2レンジ) ◆精度     常    温 : ±(3%read+0.1 m/s)           0~700℃ : ±(7%read+0.4 m/s) ◆風速応答  2段切替 ◆温度域  ①V-02-ADN200・・・・・-50~+200℃  ②V-02-ADN300・・・・・-50~+300℃  ③V-02-ADN500・・・・・-50~+500℃  ④V-02-ADN700・・・・・-50~+700℃

風速測定値 0.1~5.00 ,5.0~50.0 m/s            (自動切替2レンジ) ◆精度     常    温 : ±(3%read+0.1 m/s)           0~700℃ : ±(7%read+0.4 m/s) ◆風速応答  2段切替 ◆温度域  ①V-02-ADN200・・・・・-50~+200℃  ②V-02-ADN300・・・・・-50~+300℃  ③V-02-ADN500・・・・・-50~+500℃  ④V-02-ADN700・・・・・-50~+700℃

◆風速測定値 0.1~4.99m/s            5.0~50.0m/s           (自動切替2レンジ)  精度      ±3%/FS ◆静圧・差圧測定域 0~±2000Pa  精度          ±2%/FS ◆温度域  ①V-02-ADPN200・・・・・-100~+200℃  ②V-02-ADPN300・・・・・-100~+300℃  ③V-02-ADPN500・・・・・-100~+500℃  ④V-02-ADPN700・・・・・-100~+700℃  ⑤V-02-ADPN850・・・・・-100~+850℃

SKU: CEN0074

APPLICATION       Measuring volumetric flow rates or flow velocities in ducts     Measuring the temperature and humidity of flows     HVAC system performance     FEATURES       Fast response.     Telescoping hot wire probe.     Air flow measure: CMM、CFM.     Air velocity measurement: m/s, km/hr, ft/min, MPH, Knots & build in temperature ºC / ºF, humidity RH.     Large LCD display with backlight.     Min/Max/Avg & 2/3Vmax function.     Data Hold function.     With USB interface supply power.           Battery Life indicator.     Adjustable auto power off timer.     Air velocity compensation in atmospheric pressure.     Tilt Stand.   SPECIFICATIONS   Velocity Probe Range:         0 to 25 m/s(0 to 5000 ft/min) 0 to 999900 m3/min(ft3/min) -20 ºC ~60 ºC (-4 ºF ~140 ºC) 0~100%RH Resolution:                           0.01 m/s(1 ft/min) 0.001 m3/min(ft3/min) 0.1 ºC /ºF 0.1%RH Accuracy:                              (at 23 ºC ±  5 ºC <80%RH) ±3% of reading ± 1%FS (0 to 20 m/s) ±5% of reading ± 1%FS (20 to 25...