|
|
Fluke 705 Loop Calibrator
|
|
A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
"Span Check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Single 9V battery that is easily changed.
0 - 20 mA or 4 - 20 mA default start up modes.
|
Loop Calibrators
|
|
|
|
|
|
|
Fluke 707 Loop Calibrator
|
|
Large display and simple, quick-click interface for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015%, superior to other loop calibrators in this price range
1µA resolution for mA source, simulate and measure
Push button 25% steps for fast, easy linearity checks
0-100% "span check" for fast confirmation of zeroand span
Measures V dc to 28 V
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
Single 9 V battery that is easily changed
0-20 mA or 4-20 mA default start up modes
Innovative output adjustment dial with 1 µAand 100 µA resolution
HART™ mode connects 250 W resistor in serieswith 24 V loop for compatibility with HART communicators.
Also available Fluke 707EX Intrinsically safe model
|
Loop Calibrators
|
|
|
|
|
|
|
Fluke 1577 and 1587 Insulation Multimeters
|
|
Large display with backlight
Insulation test (1587: 0.01 Mohm to 2 Gohm), (1577: 0.1 Mohm to 600 Mohm)
Insulation test voltages (1587: 50 V, 100 V, 250 V, 500 V, 1000 V), (1577: 500 V, 1000 V)
Live circuit detection prevents insulation test if voltage> 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (W), Continuity
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Rugged, utility hard case allows you to bring everything you need for the job
3-year warranty
|
Megohmmeters
|
|
|
|
|
|
|
Fluke 1503 2000 MΩ Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.1MΩ to 2000MΩ
Insulation Test Voltages: 500 V, 1000 V
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 K Ω
Save battery power with auto Power off
Read measurements easily with large, backlit display
CAT IV 600 V over-voltage category rating for added user protection
|
Megohmmeters
|
|
|
|
|
|
|
Fluke 1507 Insulation Resistance Multimeter
|
|
Insulation Test Range: 0.01MΩ to 10GΩ
Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V
Automatic calculation of Polarization Index and Dielectric Absorption Ratio saves both time and money
Compare (Pass/Fail) function makes repetitive tests simple and easy
Saves both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
Repetitive or hard-to-reach testing is easy with the remote test probe
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 Ω to 20.00 K Ω
Save battery power with auto Power off
Read measurements easily with large, backlit display
CAT IV 600 V over-voltage category rating for added user protection
|
Megohmmeters
|
|
|
|
|
|
|
Fluke 725 Multifunction Process Calibrator
|
|
Support flow meter testing with frequency and CPM functions
Perform fast linearity tests with auto- step and auto-ramp features
Power transmitters during test using loop supply with simultaneous mA measurement
Store frequently used test setups for later use
Backlight lets you work in poor light
Large battery capacity of four AA cells
Battery door for easy changes
Also available Fluke 725EX Intrinsically safe model
|
Multifunction Calibrators
|
|
|
|
|
|
|
Fluke 726 Precision Multifunction Process Calibrator
|
|
More precise measurement and calibration source performance, accuracies of 0.01%
Transmitter error% calculation, interpret calibration results without a calculator
Memory storage for up to 8 calibration results, return stored calibration data from the field for later analysis
Frequency totalizer and frequency pulse train source mode for enhanced flow meter testing
HART mode inserts 250 ohm resistor in mA measure and source for compatibility with HART instrumentation
Integrated pressure switch test allows you to capture the set, reset and deadband of a switch
Custom RTD curves, add calibration constants for certified RTD probes for enhanced temperature measurement
New voltage input protection design for improved reliability
Two separate channels; measure, source and view process signals simultaneously
Measure volts, mA, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters
Source/simulate volts, mA, thermocouples, RTDs, frequency, and pressure to calibrate transmitters
Measure or source pressure using any of 29 Fluke 700Pxx Pressure Modules
Source mA with simultaneous pressure measurement to conduct valve and I/P tests
Perform fast linearity... |
Multifunction Calibrators
|
|
|
|
|
|
|
Fluke 985 Six channel Particle Counter, 0.3 μm to 10 μm Range
|
|
Six channels and particle size range 0.3 μm to 10 μm
Ultra-lightweight and ergonomic design for easy single-hand operation
Ten hours of standard-use battery life
Large 3.5 inch QVGC color display with backlight, intuitive icons, and large font options
10,000 records stored for easy access to historical data
Data can be viewed in traditional tabular or trend graph
Configurable display, sample methods, and alarm setting for sample size count (raw count, per cubic feet, cubic meter, or liter)
Data export to USB memory stick or direct connection to PC via USB cable. No special software required to view Excel compatible files
Ethernet enabled for accessing data via internet browser.
USB/Ethernet charge cradle ensures unit always ready for use
Administrator password control (optional) for added security
Meets ISO 21501, JIS B9921, and CE standards
|
Particle Counter
|
|
|
|
|