Fluke 187, Fluke 189 and Fluke 189/FVF2 Kit True-rms Digital Multimeters Discontinued
|
|
Basic DC accuracy of 0.025% at 50,000-counts
True-RMS AC, AC+DC, dBm, dBV
100 kHz AC bandwidth
Frequency Counter 0.5 Hz - 1 MHz
Capacitance 0.0 1nF - 50 mF
Duty cycle and pulse width measurements
Multiple reading display with bargraph and two-level backlight
Temperature readings in C or F using optional K-type thermocouple adapter (80AK) and probe
MIN/MAX/AVERAGE with real-time timestamp values in real-time
250 µS Fast MIN/MAX for peak transient capture
Document, store and analyze measurements with optional FlukeView Forms Software
Internal memory allows for stand alone logging and storage of up to 1000 measurements. (Fluke 189 Only)
Lifetime warranty
|
Fuses
|
|
|
|
|
|
|
Fluke 1621 Earth Ground Testers
|
|
3-pole Fall-of-Potential earth testing for basic measurements
2-pole resistance measurements for added versatility
Easily capture values with single-button operation
Ensure accurate measurements with automatic 'noise' voltage detection
Hazardous voltage warning offers increased user protection
Clearly read and record data with a large, backlit display
Rugged holster and design for tough work environments
Portable size allows for easy transportation
Instantly be alerted to measurements outside of your set limit, when you use the adjustable limit setting
600 V Cat II
|
Ground Testers
|
|
|
|
|
|
|
Fluke 1623 GEO Earth Ground Tester - Basic
|
|
One-button measurement concept
3 - and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-pole resistance measurement AC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Measuring frequency 128 Hz
For advanced model See Fluke 1625
|
Ground Testers
|
|
|
|
|
|
|
Fluke 1625 GEO Earth Ground Testers - Advanced
|
|
3 - and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-pole resistance measurement AC
2- and 4-pole resistance measurement DC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Earth impedance measurement at 55 Hz
Automatic frequency control (AFC) (94, 105, 111, 128 Hz)
Measuring voltage switchable 20/48V
Programmable limits, settings
Continuity with buzzer
For the Basic model See Fluke 1623
|
Ground Testers
|
|
|
|
|
|
|
Fluke 1630 Earth Ground Clamp Meter
|
|
A wide ground loop resistance range, from 0.025 Ω to1500 Ω, to satisfy all requirements
Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars
Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect - ideal for system troubleshooting
Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
User-defined HI / LO Alarm limits, for rapid measurement evaluation
Handy 'display hold' button for capturing readings in hard-to-reach places
Time saving memory function automatically records and stores measured values
Automatic self calibration ensures correct measurement every time>
Overload protection: 200 A
Carrying case and resistance test loop included
≥ 8 hours battery life (continuous operation)
|
Ground Testers
|
|
|
|
|
|
|
Fluke 971 Temperature Humidity Meter
|
|
Backlit dual display of humidity and temperature
Measures dew point and wet bulb temperatures
99 record storage capacity
Ergonomic design with belt clip and protective holster
Quick-response capacitance sensor with twist-open protective cover
Compact and lightweight (188 g/6.6 oz)
Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
Relative humidity from 5 % to 95 %
Min/Max/Avg Data hold
Low battery indicator
|
Humidity Meter
|
|
|
|
|
|
|
Fluke FoodPro Food Safety Infrared Non-Contact Thermometers
|
|
Features:
Non-contact temperature scans for safe, easy and fast surface temperature readings without risk of cross-contamination
HACCP check lights for instant recognition of safe/unsafe temperatures
LED target illumination highlights the entire measurement spot for accurate targeting
NSF certified and hand washable (non-submersible)
|
Infrared Thermometers
|
|
|
|
|
|
|
Fluke FoodPro Plus Food Safety Infrared Non-Contact Thermometers
|
|
Food Pro Plus Only:
Contact temperature measurements with field replaceable probe for internal readings
Countdown timer with audible alarm for line check audit reminders
Backlit display for clear readings in poorly lit areas
MAX temperature displayed for quick reference
|