Fluke 8808A 120V, 5.5 Digital Bench Multimeter
|
|
5.5 digit resolution
Dual Display
Measures V dc/ac, I dc/ac, Ω, Freq, Continuity, Diode
Basic V dc accuracy of up to 0.015%
Min, Max, Rel, dB, dBm
2x4 Wire Ohms measurement technique
Dedicated dc leakage current ranges
Six dedicated buttons for fast access to instrument setups
Hi/Lo limit compare for Pass/Fail testing
|
Benchtop Multimeters
|
|
|
|
|
|
|
Fluke 8845A 6.5 Digit Precision Digital Bench Multimeter, 35 ppm
|
|
6.5 digit resolution
Basic V dc accuracy of up to 0.0035 %
Dual display
100 μA to 10 A current range, with up to 100 pA resolution
Wide ohms range from 10 Ω to 1 GΩ with up to 10 μΩ resolution
2 x 4 ohms 4-wire measurement technique
Measures frequency and period
Fluke 45 and Agilent 34401A emulation
Graphical display
Trendplot paperless recorder mode, statistics, histogram
CAT I 1000 V, CAT II 600 V
For the 24 ppm Model See Fluke 8846A
|
Benchtop Multimeters
|
|
|
|
|
|
|
Fluke 8846A 6.5 Digit Precision Digital Bench Multimeter, 24 ppm
|
|
6.5 digit resolution
Basic V dc accuracy of up to 0.0024 %
Dual display
100 μA to 10 A current range, with up to 100 pA resolution
Wide ohms range from 10 Ω to 1 GΩ with up to 10 μΩ resolution
2 x 4 ohms 4-wire measurement technique
Both models measure frequency and period
Measures capacitance and temperature
USB memory drive port
Fluke 45 and Agilent 34401A emulation
Graphical display
Trendplot paperless recorder mode, statistics, histogram
CAT I 1000 V, CAT II 600 V
For the 35 ppm Model See Fluke 8845A
|
Benchtop Multimeters
|
|
|
|
|
|
|
Fluke 705 Loop Calibrator
|
|
A large display and simple, pushbutton interface for ease of use.
Simultaneous mA and % readout for quick, easy interpretation of readings.
mA accuracy of 0.02%
Push button 25% steps for fast, easy linearity checks. Save time over traditional knob type controls.
"Span Check" for fast confirmation of zero and span.
Selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
Single 9V battery that is easily changed.
0 - 20 mA or 4 - 20 mA default start up modes.
|
Calibrators
|
|
|
|
|
|
|
Fluke 707 Loop Calibrator
|
|
Large display and simple, quick-click interface for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015%, superior to other loop calibrators in this price range
1µA resolution for mA source, simulate and measure
Push button 25% steps for fast, easy linearity checks
0-100% "span check" for fast confirmation of zeroand span
Measures V dc to 28 V
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
Single 9 V battery that is easily changed
0-20 mA or 4-20 mA default start up modes
Innovative output adjustment dial with 1 µAand 100 µA resolution
HART™ mode connects 250 W resistor in serieswith 24 V loop for compatibility with HART communicators.
Also available Fluke 707EX Intrinsically safe model
|
Calibrators
|
|
|
|
|
|
|
Fluke 707EX Intrinsically Safe Loop Calibrator
|
|
ATEX Intrinsic Safe Certification for use in classified areas.
Large display and simple, quick-click push rotary button for easy one-handed operation
Simultaneous mA and % readout for quick, easy, interpretation of readings
mA accuracy of 0.015 %, superior to other loop calibrators
1 µA resolution for mA source, simulate and measure
Push button with 25 % steps for fast, easy linearity checks
0-100 % "span check" for fast confirmation of zero and span
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests
Internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM
Measures V dc to 28 V
Single 9 V battery that is easily changed
Innovative output adjustment dial with 1µA and 100 µA resolution
HART® compatible resistance is connected in series with the loop supply for compatibility with HART communicators
|
Calibrators
|
|
|
|
|
|
|
Fluke 712 RTD Process Calibrator
|
|
Measure temperature from RTD output
Simulate RTD output
Operates with seven types of RTDs
Measure additional RTDs using Ohms measurement function
Simulate additional RTDs using Ohms source function
°F or °C selectable
Four shrouded banana jacks
Compatible with Rosemount® pulsed RTD transmitters(pulses > 100ms)
|
Calibrators
|
|
|
|
|
|
|
Fluke 714 Thermocouple Calibrator
|
|
Measure temperature from Thermocouple output
Simulate Thermocouple output
Operable with nine types of thermocouples
Calibrate linear Thermocouple transmitter with mV source function
Selectable °F or °C
Thermocouple mini-jack termination
|
Calibrators
|
|
|
|
|