Fluke 902 True-rms HVAC Clamp Meter
|
|
Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements
Small body and jaws fit perfectly in your hand and into tight places
Handy 'Display Hold' button keeps measurements on the display
Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
Large, backlit display (on most models) is easy-to-see
Auto shut-off maximizes battery life so the meter works when you need it
Three year warranty
|
AC Leakage Clamp Meter
|
|
|
|
|
|
|
Fluke 771 Milliamp Process Clamp Meter
|
|
Measure mA signals for PLC and control system analog I/O
Measure 4 to 20 mA output signals from transmitters without breaking the loop
Best in class 0.2 % accuracy
Resolution and sensitivity to 0.01 mA
Hold function captures and displays changing measurements
Dual backlit display with both mA measurement and percent of 4 to 20 mA span
Measurement Spotlight illuminates hard to see wires in dark enclosures
Detachable clamp with extension cable for measurements in tight locations
Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight
|
AC Leakage Clamp Meter
|
|
|
|
|
|
|
Fluke 772 Milliamp Process Clamp Meter
|
|
Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter
Source 4 to 20 mA signals for testing control system I/O or I/Ps
Simulate 4 to 20 mA signals for testing control system I/O
Measure 4 to 20 mA signals with in-circuit measurement
Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters
Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing
Power saving features, auto-off, backlight timeout extend battery life
|
AC Leakage Clamp Meter
|
|
|
|
|
|
|
Fluke 773 Milliamp Process Clamp Meter
|
|
DC voltage measurement to verify 24 V power supplies or voltage I/O signals
Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal
Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop
mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators
Voltage output linear ramp or 25% step output
Automatically change the voltage output for remote testing
|
AC Leakage Clamp Meter
|
|
|
|
|
|
|
Fluke 922 and 922/Kit Airflow Meter/Micromanometer
|
|
Powerful meter provides differential and static pressure, air velocity and flow readings
Convenient colored hoses help proper interpretation of pressure readings
Easy to use without sacrificing performance
Bright, backlit display for clear viewing in all environments
User-defined duct shape and size for maximum airflow accuracy
Resolution down to 0.001 in H2O
99 point data storage capacity
Min/Max/Average/Hold functions for easy data analysis
Auto power off saves battery life
|
Air Quality Testers
|
|
|
|
|
|
|
Fluke 971 Temperature Humidity Meter
|
|
Backlit dual display of humidity and temperature
Measures dew point and wet bulb temperatures
99 record storage capacity
Ergonomic design with belt clip and protective holster
Quick-response capacitance sensor with twist-open protective cover
Compact and lightweight (188 g/6.6 oz)
Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
Relative humidity from 5 % to 95 %
Min/Max/Avg Data hold
Low battery indicator
|
Air Quality Testers
|
|
|
|
|
|
|
Fluke 975 and 975V AirMeter
|
|
Simultaneously measures, logs, and displays temperature, humidity, CO2, and CO on a bright, backlit LCD display
One-touch air flow and velocity with available probe (Included with Fluke 975V, optional with Fluke 975)
Wet bulb and dew point temperature
% of outside air calculation
CO2 and CO field calibration feature
Self-test function at startup
Auto-backlight
Automatically compensates for barometric pressure changes
Min/Max/Average on all measured and calculated readings
Multi-language user interface
Metric or standard units
Audible and visual threshold alarms
Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
Keypad lock for security
Included FlukeView Forms® software
|
Air Quality Testers
|
|
|
|
|
|
|
Fluke 985 Six channel Particle Counter, 0.3 μm to 10 μm Range
|
|
Six channels and particle size range 0.3 μm to 10 μm
Ultra-lightweight and ergonomic design for easy single-hand operation
Ten hours of standard-use battery life
Large 3.5 inch QVGC color display with backlight, intuitive icons, and large font options
10,000 records stored for easy access to historical data
Data can be viewed in traditional tabular or trend graph
Configurable display, sample methods, and alarm setting for sample size count (raw count, per cubic feet, cubic meter, or liter)
Data export to USB memory stick or direct connection to PC via USB cable. No special software required to view Excel compatible files
Ethernet enabled for accessing data via internet browser.
USB/Ethernet charge cradle ensures unit always ready for use
Administrator password control (optional) for added security
Meets ISO 21501, JIS B9921, and CE standards
|