SEW-Taiwan

SEW New

  • Filter

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.● Packaging...packed completely with AL-21 test leads, hFE leads,   fuse, instruction manual.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g  Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and db measurement.● With stand...makes reading and measuring easy.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC dB -10dB~+22dB(for 10VAC)~+62dB hFE 0-1000 ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V Dimensions 100(L) × 150(W) × 41(D)mm Weight (battery included) Approx. 300g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V EN61010-2-030 EN61326-1

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● Safety features...safety fused, safety "OFF" position.● hFE and dB measurement.● LCD check function.● Battery test function.● Continuity test function.● With stand...makes reading and measuring easy.      SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 200k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 9kΩ/V AC dB -10dB~+22dB hFE 0-1000 LED check   ˇ Battery check GOOD or BAD ICEO 150uA, 1.5mA, 15mA, 150mA LV 3V~0V Dimensions 100(L) × 150(W) × 41(D) mm Weight (battery included) Approx. 340g Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard EN61010-1 CAT II 1000V...

FEATURES ● High quality Taut Band movement.● Easy to read 3-color scale for mistake proof reading.● Mirror scale: makes reading pointer easy.● Safety features on all ranges.● Safety features: safety fused and safety “OFF” position.● dB measurement.● Built-in stand makes reading and measuring easy.     SPECIFICATIONS       DC Voltage     Ranges 0.25 / 1 / 2.5 / 10 / 50 / 250 / 1000V Accuracy ±2% of full scale Sensitivity 50kΩ / V AC Voltage     Ranges 2.5 / 10 / 50 / 250 / 1000V Accuracy ±3% of full scale Sensitivity 10kΩ / V Decibelmeter -20 to 62dB 0dB=1mW / 600Ω Direct Scale:-20 to +10dB DC Current     Ranges 25uA/1mA/25mA/500mA, 10A(on separate input) Accuracy ±2% of full scale Sensitivity 250mV AC Current     Ranges 10A Accuracy ±3% of full scale Resistance     Ranges R × 1           0.2 to 20kΩ R ×...

FEATURES ● Wiring check.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● Sense automatically 50 or 60 Hz.● No battery required.● Simple operation.● Current injected in phase with the voltage.● Fused.● Wide operating voltage (195Vac to 265Vac).● Other voltage optional (110V).● Robust.     SPECIFICATIONS         Wiring check LEDs Line-Neutral = Green Line-Earth = Green Neutral-Earth =Red Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection Yes by NTC sensor Test stopped indication by Red Led. Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±3% of full scale Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 150(L) × 73(W) × 50(D)mm Weight Approx. 220g Safety standard EN 61010-1 CAT III 265V EN 61326-1

FEATURES ● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).     SPECIFICATIONS             Current settings 10-50mA@230Vac> Current selection Knob Frequency of operation 50/60 Hz Sinusoidal Over-Temperature Protection NO Operating voltage (L-E) 230 Vac ±15% Meter accuracy ±1% of full scale Protection Fused (200mA 250V) Operating temperature -5°C to 45°C Storage temperature -10°C to 55°C Dimensions 170(L) × 165(W) × 92(D)mm Weight Approx. 730g Safety standard EN 50081-1 EN 50082-1

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 2500V  5000V Measuring ranges 0-100GΩ 0-200GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 5000V 10000V Measuring ranges 0-200GΩ 0-400GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries