Description: * WBGT (wet-bulb globe temperature) was developed as a monitoring basis at US military training camps and became widespread for the use in workplaces and sports situation It is suggested in the international standard ISO 7243, OSHA (US Occupation Safety), Japan Society for Occupational Health and the SMA (Sports Medicine Australia) to establish the permissible heat exposure limits in health, sports or other physical activities.* Measurement : WBGT value (Indoor/Outdoor Wet bulb globe temperature), Black globe temperature, Humidity, Air temperature, Wet bulb temperature, Dew point Temp..* Measurement function : 1. Wet bulb globe temperature (WBGT): Indoor : 0 oC to 59 oC. Outdoor : 0 oC to 56 oC. 2. Black globe Temp (TG) : 0 to 80 oC. 3. Air temperature (TA) : 0 to 50 oC. 4. Wet bulb temperature (WB) : -21.6 oC to 50.0 oC. 5. Humidity : 5 % to 95 % R.H.. 6. Dew point Temp. : -25.3 oC to 48.9 oC.* Unit : oC,oF, Resolution : 0.1 degree.* Adjustable WBGT alarm setting with buzzer sound output.* Control and monitor of physical activity in hot environment to limit the danger of heatrelated injuries.* Globe temperature measurement...
* Dual & differential input, 200 mbar x 0.1 mbar.* Unit : mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H2O, meter/H2O, Atmosphere.* Data hold, Memory (Max., Min.).* RS232/USB computer interface.* Application : Industrial, laboratory, schools, heating, ventilation, hospital, medical...* Size : 180 x 72 x 32 mm.
Description: MANOMETER, 2000 mbar, differential input Model : LUT0068 PM-9100 * Dual & differential input, 2000 mbar x 1 mbar. * mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H20, meter/H2O, Atmosphere. * Data hold, Memory(Max.,Min.), RS232. * Application : Industrial, laboratory, schools,heating, ventilation, hospital, medical... * Size : 180 x 72 x 32 mm.
*Does not include transducer-PS-100xxBAR* Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary when change a new sensor.* Bar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H20, meter/H2O, Atmosphere.* Data hold, Memory (Max., Min.), RS232.* Size : 180 x 72 x 32 mm.Pressure Port Connector : PS 1/4", 19 teeth per inch.*Transducer can be used for water and air pressure.
*Does not include transducer-PS-100xxBAR* Meter connects with 2, 5, 10, 20, 50, 100, 400 bar sensor, no calibration procedures are necessary when change a new sensor.* Bar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H20, meter/H2O, Atmosphere.* Data hold, Memory (Max., Min.), RS232.* Size : 180 x 72 x 32 mm.Pressure Port Connector : PS 1/4", 19 teeth per inch.*Transducer can be used for water and air pressure.