• Filter

The FD-800v2 Resolution 0.01% employs a dual temperature sensing method to achieve highly precise moisture measurements. In addition to the thermistor that measures the environment temperature within the drying chamber, it is mounted with a radiation thermometer that measures the sample temperature directly without contact.

Price: 1850,00 $

KKI 6163 Wireless Vantage Pro2 with UV and Solar Radiation Sensors and 24-Hour Fan-Aspirated Radiation Shield is a must-have weather station for those climates that experience very warm temperatures! KKI 6163 Wireless Vantage Pro2 with UV and Solar Radiation Sensors and 24-Hour Fan-Aspirated Radiation Shield is a must-have weather station for those climates that experience very warm temperatures! This upgraded Vantage Pro2 Plus model includes a fan-aspirated radiation shield that combines active and passive aspiration to minimize the effects of radiation. Solar-powered fans operate during the day and then shut down at night when the effects of radiation are less, keeping the sensors cool and accurate. The Vantage Pro2 Plus system includes a console unit and an innovative integrated sensor suite that includes a rain collector with self-emptying bucket, temperature and humidity sensors and an anemometer. The sensor suite is housed inside a radiation shield, protecting the sensors against solar radiation and additional sources of reflected and/or radiated heat. This high-tech Vantage Pro2 Plus model from Davis Instruments also adds two sensors not included with the...

Custom microprocessor controlled for highest accuracy and reliability. • 3 LEDs for checking correct wiring status. • 15mA LOOP measurement:LOOP impedance 2000Ω range measurement is carried out with low test current (15mA).The current will not cause tripping out involved RCD even the one with the lowest nominal differential current (30mA). • Direct reading of Prospective Short Circuit Current (PSC). • Safe voltage measurement function. • Large custom digital display readout on all models. • Measure low loop resistances(resolution of 0.01Ω) • Automatic lock-out if test resister overheats. • Large custom digital display readout . • Visual indication of reversed phase and neutral wiring at socket. • Designed to IP54 Rating • Complies with IEC 61557

• Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. • Dual Display allows simultaneous measurements like Loop & PFC/PSC. • Two wire connection for Loop L-L, L-N and PSC testing is possible. • Phase rotation, Voltage and Frequency measurements. • Lock-down test button for 'hands free' testing with auto-start operation.   • Display and front panel keyboards with Backlight to be visible in dark places. • Water and Dust proof (IP54)

Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current.

  • Phase Indicator with open phase checker • Phase indicator designed to check the presence of open phase and also the phase sequence by rotating disk and lamps. • Can check a wide range of 3-phase power source from 110V to 600V.