KKI MIT1025IN 10KV HIGH VOLTAGE INSULATION TESTER 10KV -1 YEAR WARRANTY
|
|
FEATURES
• 2 Lines × 16 Characters LCD • Microprocessor-controlled • Tests insulation resistance up to 2 TΩ • 4 Insulation test voltages: 1000V, 2500V, 5000V, 10000V • AC / DC Voltmeter (30~600V) • Short-circuit current up to 5mA • PI (Polarization Index) indication • DAR (Dielectric Absorption Ratio) indication • Auto-ranging on all insulation ranges • Auto-hold function to freeze reading • Overload protection • Adjustable testing duration: 1~30 minutes • Internal memory for data storage • Displays testing duration for insulation measurement • Auto-off function • 200 measurement results can be saved in memory and recalled on display
SPECIFICATIONS
Test voltage
1000V, 2500V, 5000V,10000V
Insulation resistance
200GΩ / 1000V 500GΩ / 2500V 1TΩ / 5000V 2TΩ / 10000V
Accuracy
±(5.0%rdg + 5dgt)
Resolution
1000MΩ: 1MΩ 10GΩ: 0.01GΩ 100GΩ: 0.1GΩ 1TΩ: 1GΩ 2TΩ: 10GΩ
Short circuit current
up to 5mA
PI (Polarization... |
Insulation (Resistance) testers
|
|
|
|
|
|
|
KYO0071-Kyoritsu 8031CE Phase Indicator
|
|
•
Phase Indicator with open phase checker
•
Phase indicator designed to check the presence of open phase and also the phase sequence by rotating disk and lamps.
•
Can check a wide range of 3-phase power source from 110V to 600V.
|
Phase sequence indicators
|
|
|
|
|
|
|
KYO0146-Kyoritsu 8031F Phase Rotation Tester with fused test leads
|
|
•
KEW8031F is designed to check phase sequence.Lamps provided on the unit will also tell you if a phase is open.
•
Can check a wide range of 3-phase power source from 110V to 600V.Sealed against dust, the unit ensures trouble-free performance.
•
Small, Lightweight and portable.Designed for maximum ease of operation and ruggedness.
•
No exposed metal parts, Safety features are incorporated including the instant push button switch operation.
|
Phase sequence indicators
|
|
|
|
|
|
|
KYO0149-8035 Non-Contact Safety Phase Indicator
|
|
•
New technology permits safe testing, without the need of direct contact between probes and live wires.
•
The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm.
•
Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones.
•
The instrument can be fixed to a metal panel via the magnet on the back side.
•
Wide measuring range for 3 phase installations from 70V to 1000V AC.
•
Super brightness function permits clear LED's indication also in sunshine.
•
Complies with IEC 61010-1 CAT.IV 600V and CAT.III 1000V.
|
Phase sequence indicators
|
|
|
|
|
|
|
SEW0049-4183 CP CABLE PHASING METER
|
|
● Safely operates at low voltage ● Measures system voltage. ● Measures capacitance of test point if system voltage is known. ● Checks phase rotation of cables. ● Phases out cables. ● Rugged - comes with portable case. ● Operates from potential test point of elbow connectors. ● Battery operated. |
Phase sequence indicators
|
|
|
|
|
|
|
SEW0016-NON CONTACT SAFETY PHASE SEQUENCE DETECTOR WITH MAGNETIC BACK COVER,LED-1 YEAR WARRANTY
|
|
FEATURES
● This is a Non-Contact phase detector with flashing LEDs and a beeping buzzer to show the detection of AC 3-phase sequence. ● Two functions in one unit: phase sequence and phase sequence / rotation. ● Convenient brightness switch to make the indication visible in dim areas or sunlight. ● Back cover magnet attaches the instrument to the AC distribution panel offer easy measurement. ● 3-Phase AC 75 to 1000V is fitted for detection. ● Detect frequency range is from 45 to 65Hz.
SPECIFICATIONS
Measurement principle
:
Static induction
Input voltage
:
75~1000Vac
Frequency range
:
45-65Hz
Auto-off
:
5 min. after power on
without detection
Low battery warning
:
Power LED flashes at
4.6±0.1V or less
Operating temperature
& humidity
:
0°C ~ 40°C Max. 80% R.H.
Storage temperature
& humidity
:
-10°C ~ 50°C Max. 80% R.H.
Cable length
:
Approx. 800mm
Dimensions
:
118(L) ×... |
Phase sequence indicators
|
|
|
|
|
|
|
SEW0031-895PR NON CONTACT PHASE ROTATION METER
|
|
FEATURES
● Non-contact detector clips. No metal contact points to advocate greater safety. ● Dual functions : open phase and phase sequence detection. ● Designed for checking a wider range of 3-phase power sources. ● LED display lights with buzzer indicator. ● Brightness button feature for better visibility in dimly lit areas or sunlight. ● Magnetic mounting feature.
SPECIFICATIONS
Measurement principle
:
Static induction
Input voltage
:
75-1000 Vac
Frequency range
:
45-65 Hz
Auto-off
:
5 min. after power on
without detection
Low battery warning
:
Power LED flashes at
7V ± 0.2 or less
Operating temperature
& humidity
:
0°C ~ 40°C Max. 80% R.H.
Storage temperature
& humidity
:
-10°C ~ 50°C Max. 80% R.H.
Cable length
:
Approx. 800mm
Dimensions
:
128(L) × 72(W) × 44(D) mm
Weight
(battery included)
:
Approx. 380g
Power source
:
9V(6LF22) × 1
Safety standard
:
EN 61010-1 CAT III 1000V... |
Phase sequence indicators
|
|
|
|
|
|
|
LUT0013-DC-515 DIGITAL VENIER CALIPER
|
|
DIGITAL CALIPER
Model : DC-515
SPECIFICATIONS
Display
* 4.7 mm ( 0.19" ) LCD, 6 digits. * " - " for minus sign. * " mm " for mm measuring unit. *" IN " for inch measuring unit.
Measurement range
0 to 150 mm ( 0 to 6 inch ).
Resolution
0.01 mm/0.0005 inch.
Accuracy
± 0.03 mm/0.0015 inch.
Max. measuring speed
1.5 m/sec., 60 inch/sec.
Measuring unit
Inch & mm, changed by pushing the button, true conversion.
Zero setting
Zero setting at any position within the measuring range.
Polarity
Automatic switching, '-' indicates negative polarity.
Operating Temp.
0 to 40 ( 32 to 104 ).℃℉
Storage Temp.
-20 to 70 (-4 to 194 ).℃℉
Operating Humidity
Less than 80% RH.
Power Supply
One battery, 1.5V, silver oxide.
Power Consumption
Approx. DC 18 uA. Battery approx. Approx. 5000 hours for continuous use.
Data output
Serial output for computer interface & printer.
Dimension
Length 237 mm(9.4 inch).
Weight
Approx.... |
Calipers/Micrometers
|
|
|
|
|