Bante930 Precision pH/ORP/Ion/°C/°F Meter
|
|
Bante930 is a high accuracy meter used for measuring the ion
concentration, ORP and pH values of liquids. The meter widely
used in environmental studies, chemical labs, swimming pools,
spas to monitor the chemical reaction of water.
Features:
During the pH mode, Up to 5 points push-button calibration with auto-
buffer recognition.
Selectable pH buffer standards and temperature units.
Automatically calculates and displays electrode slope after calibration.
During ORP mode, Single point offset calibration allows user adjusts
displayed value to a known standard.
Absolute or Relative millivolt (R.mV) measurement provides accurate
ORP readings.
During the ion mode, 2 to 5 points push-button calibration from low to
high concentrations.
Selectable multiple concentration units, including ppm, mg/L and mol/L.
Direct readout ion concentration simplifies the elaborate measurement
process.
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire... |
pH Meters
|
|
|
|
|
|
|
Bante900P Portable Multi-parameter Water Quality Meter
|
|
Bante900P multi-parameter meter is capable of measuring up to
9 water quality parameters, including pH, ORP, Ion, Conductivity
TDS, Salinity, Resistivity, Dissolved Oxygen, etc.
General Features:
Automatic Temperature Compensation (ATC) ensures highly
accurate measurements over the entire range.
Calibrationdue reminder helps you to calibrate meter regularly.
Automatic endpoint function freezes stable measured values.
Help message as a operational guide to helps you understand
how to use meter.
Setup menu lets user customize the calibration points, stability
conditions, date and time to meet measurement requirements.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP.
Stored data can be transferred into PC via USB communication
interface. |
pH Meters
|
|
|
|
|
|
|
Bante901P Portable pH/Conductivity/°C/°F Meter
|
|
Bante 901P portable multi-parameter meter used for measuring
the pH, Conductivity and TDS of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface. |
pH Meters
|
|
|
|
|
|
|
Bante902P Portable pH/ORP/Conductivity/°C/°F Meter
|
|
Bante 902P portable multi-parameter meter used for measuring
the pH, ORP, Conductivity, TDS, Salinity and Resistivity of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication... |
pH Meters
|
|
|
|
|
|
|
Bante903P Portable pH/ORP/DO/°C/°F Meter
|
|
Bante 903P portable multi-parameter meter used for measuring
the pH, ORP and Dissolved Oxygen in water.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|
pH Meters
|
|
|
|
|
|
|
Bante904P Portable Conductivity/DO/°C/°F Meter
|
|
Bante 904P portable multi-parameter meter used for measuring
the Conductivity, TDS, Salinity, Resistivity and DO in water.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes calibration points, stability condition,
resolution, temperature units, date and time to meet measurement
requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|
pH Meters
|
|
|
|
|
|
|
Bante901 Precision pH/Conductivity/°C/°F Meter
|
|
Bante 901 multi-parameter meter used for measuring the pH,
Conductivity and TDS of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|
pH Meters
|
|
|
|
|
|
|
Bante902 Precision pH/ORP/Conductivity/°C/°F Meter
|
|
Bante 902 multi-parameter meter used for measuring the pH,
ORP, Conductivity, TDS, Salinity and Resistivity of liquids.
General Features:
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
Calibration due reminder prompts you to calibrate the meter regularly.
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
Manual temperature calibration provides accurate temperature value.
Help message as a operational guide to helps you understand how
to use meter.
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
Reset function can resumes all settings to factory default values.
Expanded memory stores and recalls up to 500 readings.
Built-in real-time clock stamps stored data to meets GLP standards.
Stored data can be transferred into computer via USB communication
interface.
|
pH Meters
|
|
|
|
|