Kyoritsu 8309
|
|
Floating voltage can be measured
*Floating voltage:phase to phase voltage not grounded
*KEW 5020-01:KEW 5020 logger with KEW 8309 (1 pce.)
For use with following model
5020
|
Voltage Sensor
|
|
|
|
|
|
|
Kyoritsu 8130
|
|
Can measure AC current up to 1000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
|
|
|
|
Kyoritsu 8129
|
|
Flexible for various test fields
•
Can measure AC current up to 3000A
•
Flexible and light weight by the air core coil used at the sensor part
•
Measurable conductor size:max Φ150mm
•
Designed to meet the international safety standardIEC 61010-1 CAT.III 600V
Applicable model
5010/5020 (*), 6300, 6305, 6310, 6315
|
Flexible Clamp Sensor
|
|
|
|
|
|
|
Kyoritsu 8121
|
|
Applicable model 5010/5020
Conductor size
Φ24
Rated current
AC 100A
Output voltage
AC 500mV/100A (AC 5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 3540V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 9.5Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2
Dimensions
97(L) x 59(W) x 26(D) mm
Weight
Approx.150g
Accessories
9095 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
|
|
|
Kyoritsu 8122
|
|
Applicable model 5010/5020
Conductor size
Φ40
Rated current
AC 500A
Output voltage
AC 500mV/500A (AC 1mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.9Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2
Dimensions
128(L) x 81(W) x 36(D) mm
Weight
Approx.260g
Accessories
9095 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
|
|
|
Kyoritsu 8123
|
|
Applicable model 5010/5020
Conductor size
Φ55
Rated current
AC 1000A
Output voltage
AC 500mV/1000A (AC 0.5mV/A)
Accuracy
|±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz)
Withstand voltage
AC 5350V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~40ºC, less than 85% RH (without condensation)
Output impedance
Approx. 1.5Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2
Dimensions
170(L) x 105(W) x 48(D) mm
Weight
Approx.360g
Accessories
9094 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Load current clamp sensors
|
|
|
|
|
|
|
Kyoritsu 8146
|
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
Conductor size
Φ24
Rated current
AC 30A
Output voltage
AC 1500mV/30A (AC 50mV/A)
Accuracy
0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz)
15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz)
Withstand voltage
AC 3540V for 5 seconds
Cable length
Approx. 2m
Output connector
MINI DIN 6pin
Operating temperature ranges
0~50ºC, less than 85% RH (without condensation)
Output impedance
Approx. 90Ω
Applicable standards
IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2
Dimensions
100(L) x 60(W) x 26(D) mm
Weight
Approx.150g
Accessories
9095 (Portable case), Instruction manual, Cable marker
Option
7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)
|
Leakage & Load current clamp sensors
|
|
|
|
|
|
|
Kyoritsu 8147
|
|
Applicable model
5010/5020, 6310, 6315
* Cannot be used for power measurement.
|
Leakage & Load current clamp sensors
|
|
|
|
|