|
|
CAX0024B-CHAUVIN ARNOUX 6292 200A ADVANCED MICRO-OHM METER (ORIGIN:FRANCE)
|
|
Advantages
● Resolution: 0.1 μΩ
● Test current adjustable up to 200 A
● Automatic mode: 50 A, 100 A, 150 A and 200 A
● Unlimited test duration up to 100 A
●Safe measurements: Both Sides Grounded (BSG mode)
● Internal cooling system
● Storage of up to 8,000 measurements
● Site-proof casing for difficult environments
Description
The C.A 6292 is supplied in a site-proof casing with clearly-identified connection terminals to limit the risk of errors while also allowing quick connection of your measurement leads.
The measurement results are displayed instantaneously on the LCD screen, which is backlit for easy reading. The C.A 6292 can be configured using the rotary knob on the instrument or via a PC with the USB link.
The C.A 6292 can be used to measure in total safety for both people and equipment. The BSG method allows you to maintain the earthing on both sides of the object tested in order to remove any risk due to electromagnetic induction phenomena. In this mode, the optional MR 6292 clamp can be used for current measurements up to 50 ADC.
The C.A 6292 can store in memory up to 8,000 measurement results.
Accurate measurements
According... |
Milli-Ohm meter/Micro-Ohm meters
|
|
|
|
|
|
|
DEN810-DENT USA RECORDING POWER METER WITH WIFI AND ANTENNA
|
|
Allow you to download data without opening the switch or junction box cover. Any one can steal your power meter until you have this!
>> Measures, Stores and Analyzes 144 Different Electical Parameters Including Volts, Amps, Watts, Volt-Amps (VA), Volt-Amps Reactive (VAR), Kilowatts (kW), Kilowatt Hours (kHW), Power Factor and Harmonics through 63rd |
Power analysers/Power meters
|
|
|
|
|
|
|
ARH102-Smart Power Meter With Reports (WITH ETHERNET/RS-485)
|
|
Class 0.5 bi-directional energy and full power parameters measurement.
Block or Rolling power demand measurement.
THD, indivisual harmonics, and sag/swell power quality records.
Data logging for alarm, sag, swell events with time-stamped.
Report generation for daily and monthly power usage.
Communication interfaces:Ethernet, RS485.
Communication protocol:Modbus over TCP/IP for Ethernet, Modbus for RS485.
Smart Power Meter with up to 4 channels of re-transmission analog outputs for field integration.
12 digital inputs for power system status monitoring.
2 digital relays for kWh pulse or alarm outputs.
Automatic detection of voltage & current wiring.
Multi-language support.
|
Power analysers/Power meters
|
|
|
|
|
|
|
PRO0030-6830 All-Rounded Power and Harmonics Three and Single Phase Analyser
|
|
PRO0030 BASE UNIT POWER AND HARMONICS ANALYZER WITH 3 x 1000A CLAMPS Optional: PRO0041- 3 x 3000A Flexible Clamps Optional: PRO0038- 3 x 100A Clamps |
Power analysers/Power meters
|
|
|
|
|
|
|
LUT0298-COMPLETE ADVANCED SD CARD GRAPHICAL/ WAVEFORM DATALOGGING 3-PHASE POWER & HARMONICS ANALYSER W 3 X 1200A CLAMP
|
|
Features:
•Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W •3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary •Current probe input signal/ranges with selection:Input signal (ACV):200 mV/300 mV/500 mV/1 V/2 V/3 VRanges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A. •Meter can cooperate the universal current probes •Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle •Harmonics display (1-50th order) •Simultaneous display of Harmonics and Wave form •Display of Waveform with Peak Values •Analysis of Total Harmonic Distortion ( THD ) •Graphic Phase diagram with 3-Phase system parameters •3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor •Calculated Unbalanced Current through Neutral Line ( An )
Standard Accessories:
* Instruction manual............... 1 PC * Test Leads (TL88-4AT).......... 1 Set (4 PCs) * Alligator clips (TL88-4AC) 1 Set (4 PCs) * Clamp Probe ( CP-1201 )....... 3 PCs * AC to DC 9V adapter..............1... |
Power analysers/Power meters
|
|
|
|
|
|
|
LUT0339-COMPLETE SD CARD KWH DATALOGGING 3-PHASE POWER ANALYSER/LOGGER W 3 X 1200A CLAMP - 2 YEARS WARRANTY
|
|
Features:
•Analysis for 3 phase multi-power system, 1P/2W,1P/3W, 3P/3W, 3P/4W •Voltage & Current are the True RMS value. •True Power ( KW、MW、GW ) measurement. •Apparent Power ( KVA、MVA、GVA ) measurement. •Reactive Power ( KVAR MVAR、GVAR) measurement. •Watt-Hour ( WH、SH、QH、PFH ). •Power Factor( PF )、Phase Angle( Φ ). •Voltage measurement range : 10 to 600 ACV •Current measurement range: 0.2A to 1200 ACA. •Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). •ACV input impedance is 10 Mega ohms. •Safety Standard : IEC 1010, CAT III 600V •Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves. •Measurement: * ACV * ACA * AC WATT ( True Power )AC WATT( Apparent Power )AC WATT( Reactive Power ) * Power factor * Phase angle * Frequency
Standard Accessories:
* Instruction manual.......................1 PC * Test Leads... |
Power analysers/Power meters
|
|
|
|
|
|
|
LUT0163B-Benchtop Power Meter(Watt, VA, Power factor, ACV, ACA, DCV, DCA, VAr, Whr, ohms,)
|
|
0.1 W resolution ( <1000 W ), high precision and high resolution in the low watt range, good performance , for low power LED lamp watt measurement
Supper large LCD, easy to read-out, display the Watt, Power factor, Voltage & Current value at the same time.
Accept different kinds current input signal as direct input, inductive clamp probe or CT ( current transformer ).
Auto range.
Built-in peak hold & data hold function.
RS-232 output interface.
Power supply by batteries or AC to DC adapter.
- See more at: http://www.test-measurement-australia.com.au/electrical/lutron-dw-6090a#sthash.oTAjYKvQ.dpuf
Multi-functions: Watt, VA, W hr, Power factor, ACV, ACA, DCV, DCA, Hz, ohm
True AC power measurement, not apparent power
True RMS for ACV and ACA
Display Watt, power factor, V and A simultaneously
Auto range, Peak-hold and Data-hold
RS-232 serial output interface
Watts (AC true power)
Direct input: 1W-100kW Current probe: 1W-2,000kW
VA(AC)
Direct input: 0.01VA-40kVA
Power Factor:
0.01-1.00
ACV/DCV
0.1V-600V
ACA/DCA
Direct input: 0.01A-20A Current probe: 1A-1000A
Watt Hour
Direct input:... |
Power analysers/Power meters
|
|
|
|
|
|
|
FLI0010- i7 ALL-IN-ONE THERMAL IMAGING CAMERA *NEW* WITH 'TRUE' WARRANTY
|
|
Thermal Imaging Camera140 x 140 Resolution, 29° × 29° Field of View |
Thermal imagers/thermal camera (Infrared camera)
|
|
|
|
|