Fluke TPAK ToolPak, Meter Hanging Kit
|
|
Kit includes: 9 inch hook and loop strap, universal hanger clip, hook hanger for non magnetic surfaces and a strong magnet.
Solves almost any hanging and positioning problem you may face.
The universal hanger allows you to hang your meter on nails, hooks and many other objects.
Compatible with many Fluke instruments.
One year warranty.
|
Cases and Holsters
|
|
|
|
|
|
|
Fluke 700-IV Current Shunt
|
|
Very accurate current shunt to use for verification and calibration of process control loops.
Can be used with accurate voltmeters for calibration purposes
Can be used with Fluke 74X series in mA/mA applications (74X will display mA/mA automatically) One year warranty
|
Connectors
|
|
|
|
|
|
|
Fluke 700-BCA Bar Code Adapter
|
|
Shielded four conductor cable terminated with a 9-socket D-subminiature connector and a 9-pin D-subminiature connector.
Provides interconnection and pin translation between a Fluke 743 Documenting Process Calibrator and a Hewlett Packard HBSW-8200 Bar Code Wand.
Overall length approximately 15 cm
One year warranty
|
Connectors
|
|
|
|
|
|
|
Fluke 700-BCW Bar Code Wand
|
|
This Hewlett Packard HBSW-8200 Bar Code Wand reads eight common bar code symbologies.
Code 39, Interleave 2 or 5, UPC A and E, EAN 8 and 13, Codabar, Code 128, Code 11, Code 93, and MSI Code.
Programmable via bar code labels or escape sequences. LED indicates when a bar code has been correctly decoded.
Resolution, 0.19 mm.
Usable from -20 °C to 65 °C, in ambient light to 100,00 lux.
EMI compliance per FCC part 15 Class B. ESD immunity, 25 kV.
Supports the scanned entry of procedure identification, tag ID, serial number, and operator ID to a Fluke 743 Documenting Process Calibrator.
|
Connectors
|
|
|
|
|
|
|
Fluke 787CAL Calibration Module
|
|
This Hewlett Packard HBSW-8200 Bar Code Wand reads eight common bar code symbologies.
Code 39, Interleave 2 or 5, UPC A and E, EAN 8 and 13, Codabar, Code 128, Code 11, Code 93, and MSI Code.
Programmable via bar code labels or escape sequences. LED indicates when a bar code has been correctly decoded.
Resolution, 0.19 mm.
Usable from -20 °C to 65 °C, in ambient light to 100,00 lux.
EMI compliance per FCC part 15 Class B. ESD immunity, 25 kV.
Supports the scanned entry of procedure identification, tag ID, serial number, and operator ID to a Fluke 743 Documenting Process Calibrator.
|
Connectors
|
|
|
|
|
|
|
Fluke 80i-110s AC/DC Current Clamp
|
|
Current Range: 0.1 to 100A DC or 0.1 to 70A AC
Basic Accuracy (DC to 1kHz):
100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading
Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
Bandwidth: 1Hz to 20kHz
Working Voltage: 600V AC rms
Maximum Conductor Size: 1.8 mm (.46 inch) diameter
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
|
Current Clamps
|
|
|
|
|
|
|
Fluke 90i-610s 1A to 600A AC/DC Current Probe
|
|
Current Range: 1 to 600 A DC or AC Peak
Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A)
Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A
Frequency Range: 40 Hz to 400 Hz
Working Voltage: 600 V AC rms
Maximum Conductor Diameter: 34 mm (1.34 inch)
Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
|
Current Clamps
|
|
|
|
|
|
|
Fluke i1000s AC Current Probe
|
|
Current Range: 100mA to 1000 Arms
Basic Accuracy 48Hz to 65Hz:
10A Range +/- 3% of reading + 0.1A, 100mV/A output
100A Range +/- 2% of reading + 0.5A, 10mV/A output
1000A Range +/- 1% of reading + 1A, 1mV/A output
Bandwidth: 5Hz to 100kHz
Working Voltage: 600V AC rms
Maximum Conductor Size: 54 mm (2.13 inch) diameter
Safety Rating: 600V rms. CAT III per IEC 1010-02-032
|
Current Clamps
|
|
|
|
|