MSR SHOCK LOGGERS FROM SWITZERLAND (SWISS MADE)

Sub Categories

  • Filter
  Name SKU Description Category Producer Price Location
Fluke 3585R Split-Core Current Transformers Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm) Current Clamp DMM Accys
Fluke TPS CLAMP 10 A / 1 A Clip-on Current Transformer Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 200 A / 20 A Clip-on Current Transformer Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS CLAMP 50 A / 5 A Clip-on Current Transformer Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts) Current Clamp DMM Accys
Fluke TPS FLEX 18-TF 100A/500A Thin Flex Flexible Current Probe with 18-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 24-TF 200A/1000A Thin Flex Flexible Current Probe with 24-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke TPS FLEX 36-TF 3000A/6000A Thin Flex Flexible Current Probe with 36-inch Cable For the Fluke 1760 Power Recorder Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable Current Clamp DMM Accys
Fluke 373 True-RMS 600A/600V AC Clamp Meters 600 A ac current measurement with fixed jaw 600 V ac and dc voltage measurement True-rms ac voltage and current for accurate measurements on non-linear signals Resistance measurement to 6000Ω with continuity detection 1000 µF capacitance measurement State of the art signal processing allows for use in noisy electrical environments while providing stable readings Large, easy to read, backlight display automatically sets the correct measurement range so you do not need to change switch positions while taking a measurement CAT IV 300 V, CAT III 600 V safety rating Current Clamp Meters