DKK-TOA OC-64
|
|
Low-Concentration DO Detector for Pure Water OC-64
Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants)
Micro-flow (100mL/min) with special flow cell
Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode)
Lead wire: ELW-32
|
Transmitter for Industrial Low-Concentration DO Analyzer
|
|
|
|
|
|
|
DKK-TOA SOD-35D (2-Wire Transmitter) SOC-71 (Sensor)
|
|
Polarograph type DO analyzer with intrinsically safe explosion-proof function (combined with a Zener Barrier)
Alterable output range
Types of detectors available: immersion, flow-through and fermentation-used (electrodes: ELD-017/ELD-019)
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 20 mg/L
|
Intrinsically Safe Explosion-Proof Type DO Transmitter
|
|
|
|
|
|
|
DKK-TOA XAT-200 series
|
|
Process analyzer for automating analytical techniques such as atomic absorption and etc.
Suitable for automating chemical analysis processes such as distillation, heat treatment, etc.
Example applications:
*Total chromium *Total cyanide by atomic absorption/distillation *Phenols by atomic absorption/distillation *Total mercury by oxidation-reduction atomic absorption |
Automatic Process Analyzer
|
|
|
|
|
|
|
DKK-TOA BMR-24
|
|
Compact and lightweight model in accordance with DIN standard
DC 24V power supply designed for 4-point alarm and 2-wire transmitters
Often used as a receiver of 2-wire or 4-wire transmitter (such as pH/ORP meters, conductivity analyzers and DO meters)
Meas. range
pH meter: pH; 0 - 14 70divisions (to be specified otherwise)
|
Bar Graph Meter Relay
|
|
|
|
|
|
|
DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
|
|
|
|
DKK-TOA CLF-1600
|
|
Measures residual chlorine (total or free) happened in the water chlorination process
Continuously measurement with polarographic method
1/5 reagent requirement of existing models
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 0.5/1.0 to 0 - 5/10 mg/L (ppm) (2-range)
|
Residual Chlorine Analyzer
|
|
|
|
|
|
|
DKK- TOA CLF-1610
|
|
Measures free residual chlorine of clean water continuously with the reagentless polarographic method
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)
|
Reagentless Free Chlorine Analyzer
|
|
|
|
|
|
|
DKK-TOA CD-36D/38D
|
|
Measures free residual chlorine of chlorinated samples from purification/food processing/semiconductor plants and pool without reagent
Continuous measurement by polarographic method
Meas. range
CD-36D: 0 - 2 mg/L (ppm) CD-38D: 0 - 100 mg/L (ppm)
|
Reagentless Free Chlorine Analyzer
|
|
|
|
|